INFORMATION HUB
Fire Stopping Explained
Fire stopping is the sealing of openings, gaps and joints in fire-resisting construction so that fire and smoke cannot pass through them. It is one of the most common forms of passive fire protection and one of the most frequently damaged or missed. This guide explains what fire stopping is, where it is needed, the main types of system and what makes the difference between fire stopping that works and fire stopping that does not.
What is fire stopping?
Fire-resisting walls and floors are designed to hold back fire for a set period. In practice, they are rarely solid. Pipes, cables, ducts, cable trays and other building services pass through them, and there are joints where walls meet floors, ceilings and other walls. Every one of these openings is a potential route for fire and smoke.
Fire stopping seals these openings and joints using tested products and systems, so that the wall or floor can maintain the fire performance it was designed to provide. Without suitable sealing, a 60-minute compartment wall with an open service hole may offer far less protection than intended.
Where is fire stopping needed?
Fire stopping is typically required wherever a fire-resisting element is penetrated or has a gap, including:
- Pipes passing through compartment walls and floors, whether metal or plastic.
- Cables and cable bundles, trays and trunking.
- Ventilation ductwork, where fire dampers or fire-resisting ductwork may also be needed.
- Service risers and shafts at each floor level.
- Linear joints, such as the head of a wall where it meets the slab above.
- Gaps around frames and at junctions between different types of construction.
Common types of fire-stopping product
There is no single product that suits every situation. The right choice depends on the type of wall or floor, the service passing through it, the size of the opening and the fire performance required. Common types include:
- Intumescent and acrylic sealants for smaller gaps around services and linear joints.
- Fire-resisting batts and coated boards for larger openings with multiple services.
- Pipe collars and wraps, which expand under heat to close off plastic pipes as they soften.
- Fire-resisting mortars and compounds for some floor and wall openings.
- Pillows and blocks, often used where services are likely to change.
Why tested systems matter
Fire-stopping products are tested as part of a system: a particular product, in a particular wall or floor type, with particular services, installed in a particular way. Penetration seals and linear joint seals are commonly tested to European standards and classified under BS EN 13501-2, while some older products may have been assessed against BS 476.
The test evidence or manufacturer’s data will set out the conditions under which the product achieves its rating. Using a product outside that scope, mixing products from different systems or improvising with materials that are not fire rated can mean the seal will not perform as expected. Expanding foam that is not fire rated, general-purpose sealant and loose mineral wool packing are common examples of unsuitable materials found in service openings.
Installation, labelling and records
Good fire stopping depends as much on installation as on product choice. Installers need to follow the manufacturer’s instructions on depth, density, annular gaps, backing materials and support for services. Many contractors label completed seals and keep photographic records and installation details, which helps building managers and future contractors understand what has been installed.
Third-party certification schemes, such as FIRAS or BM TRADA, assess installers’ competence and quality procedures. Using a certified installer is one way of gaining confidence in the work, although clients should still check the scope of any certification. Our guide to choosing a passive fire protection contractor covers this in more detail.
Keeping fire stopping effective over time
Fire stopping is often breached after a building is completed. New cables, replacement pipes and IT and telecoms upgrades regularly create fresh openings, and existing seals may be cut through and not reinstated. A permit-to-work system for works that affect compartment lines, combined with periodic inspection of risers, ceiling voids and plant areas, can help catch problems early. See our passive fire protection inspection checklist for practical points to look out for.
Frequently asked questions
What is the difference between fire stopping and a cavity barrier?
Fire stopping seals openings and joints in fire-resisting walls and floors. Cavity barriers close and subdivide concealed spaces such as wall cavities and ceiling voids. Both are forms of passive fire protection but they do different jobs.
Can I use expanding foam for fire stopping?
Only a fire-rated product that has been tested for that specific application should be used, and only within the limits of its test evidence. General-purpose expanding foam is not a fire-stopping product.
Who can install fire stopping?
Fire stopping should be installed by competent people who understand the products and the building’s requirements. Many clients choose contractors who hold third-party certification for the work.
How often should fire stopping be inspected?
There is no single interval that suits every building. Inspection frequency should reflect the building’s risk, use and level of ongoing alteration, and is often informed by the fire risk assessment.
This guide is general information only. The correct fire-stopping solution depends on the building, its design, the fire strategy and the products and systems specified, so get building-specific advice from a competent professional.
Related guides
Need help with fire stopping in your building or project? Lancashire Fire Security can discuss your requirements, whether you are planning new work or investigating existing seals. Email [email protected] or call 0800 038 9841.
Need advice on a passive fire protection project?
Tell us about your building, project or compliance question.
PASSIVE FIRE PROTECTION
Services | Knowledge Hub | About | Contact
Company Number: 11888399 | VAT Registration number: 373832577