What Are Cavity Barriers?
Cavity barriers are a form of passive fire protection installed inside concealed spaces in a building to stop fire and smoke spreading through them unseen. They are easy to miss once a building is finished, yet missing or poorly installed cavity barriers are a recurring finding in fire safety inspections. This guide explains what cavity barriers are, where they are used, how they differ from fire stopping and what to look out for.
What is a cavity barrier?
Many buildings contain hidden voids: the cavity in an external wall, the space above a suspended ceiling, the void beneath a raised floor, roof spaces and the gaps behind cladding or internal linings. If a fire gets into one of these spaces, it can travel quickly and out of sight, bypassing walls and floors that are designed to contain it.
A cavity barrier is a construction or product installed within a cavity to close it off or divide it into smaller sections. Its purpose is to restrict the movement of fire and smoke through the concealed space.
Where are cavity barriers needed?
Approved Document B, which supports the Building Regulations 2010 in England, gives guidance on where cavity barriers should be provided. The exact requirements depend on the building type, use and design, but cavity barriers are commonly needed:
- At the edges of cavities, including around openings such as windows and doors.
- Where a cavity meets a compartment wall or compartment floor, so the compartment line continues through the void.
- To subdivide large or extensive cavities into smaller areas.
- At junctions between external walls and separating walls or floors.
- In ceiling voids above protected escape routes, in some situations.
Cavity barriers vs fire stopping
The two terms are often confused, but they do different jobs:
- Fire stopping seals openings, gaps and joints in fire-resisting construction, such as where pipes and cables pass through a compartment wall.
- Cavity barriers close or subdivide concealed spaces within or between elements of construction.
The performance expected of each can also differ. Approved Document B sets out minimum performance for cavity barriers, and the requirement may be different from that of the compartment wall or floor they line up with. The building’s fire strategy and specification should make clear what is needed in each location.
Types of cavity barrier
Cavity barriers come in several forms, each suited to particular applications:
- Mineral wool barriers, often foil-faced or wrapped, used in ceiling voids, roof spaces and wall cavities.
- Open-state cavity barriers, used in ventilated cavities behind some cladding systems. These leave an air gap in normal conditions and use an intumescent strip that expands in a fire to close the cavity.
- Closed-state cavity barriers, which fully close the cavity at all times.
- Board-based barriers formed from fire-resisting boards in some situations.
As with all passive fire protection, a cavity barrier should be a tested product installed in line with the manufacturer’s instructions and within the scope of its test evidence. The orientation, fixing method, cavity width and the materials it fits against all affect whether it will perform as intended.
Common cavity barrier problems
Because cavity barriers are hidden once the building is finished, defects often only come to light during intrusive surveys or refurbishment. Typical problems include:
- Barriers missing altogether, particularly at compartment lines and around openings.
- Gaps between sections or around services passing through the barrier.
- Barriers poorly fixed, sagging or displaced.
- Open-state barriers installed upside down or with the wrong air gap.
- Products used in a cavity size or construction they were not tested for.
- Barriers damaged or removed during later works and not reinstated.
Checking cavity barriers in existing buildings
Inspecting cavity barriers usually means getting into concealed spaces: lifting ceiling tiles, opening access hatches or, for external walls, carrying out intrusive inspection. Building records, drawings and the fire safety information handed over on completion can help show where barriers should be. Where barriers form part of an external wall system, specialist assessment may be needed. Our inspection checklist covers practical points for building managers.
Frequently asked questions
Are cavity barriers a legal requirement?
For new building work in England, the Building Regulations 2010 include requirements on concealed spaces, and Approved Document B gives guidance on providing cavity barriers. Whether they are required in a particular location depends on the building and its design.
Can a cavity barrier have services passing through it?
Where services pass through a cavity barrier, the gap around them needs to be suitably sealed so the barrier remains effective. The manufacturer’s guidance should be followed.
What is an open-state cavity barrier?
It is a barrier that leaves an air gap for ventilation or drainage in normal use, then closes the gap in a fire as its intumescent material expands. They are commonly found behind rainscreen cladding.
How can I tell if my building has cavity barriers?
Records and drawings may show them, but confirming their presence and condition usually needs a physical inspection of the concealed spaces by a competent person.
This guide is general information only. Cavity barrier requirements depend on the building and its construction, so get building-specific advice from a competent professional.
Related guides
Need advice on cavity barriers in your building? Lancashire Fire Security can talk through your concerns and help you identify the appropriate next step. Email [email protected] or call 0800 038 9841.
Need advice on a passive fire protection project?
Tell us about your building, project or compliance question.
PASSIVE FIRE PROTECTION
Services | Knowledge Hub | About | Contact
Company Number: 11888399 | VAT Registration number: 373832577